 ====== ICS Primary Data Center ​ ====== ====== ICS Primary Data Center ​ ======
  
-Vital Statistics:+== Vital Statistics: ​December 2024 Census ==
  
   * Size:  1600 sqft   * Size:  1600 sqft
   * HVAC:  3 Units   * HVAC:  3 Units
-  * Cabinets: +  * Cabinets: ​ 42 
-  * Draw:+  * Servers (~800) 
 +    * Bare Metal 598 
 +    * Virtual Machines: 300 
 +  * [[hardware:​storage|Storage]] 
 +    * Servers: 20 
 +    * Petabytes: ​ 3.2 PB 
 +  * [[services:​network|Network]] (locally managed, 1/​10/​40GB) 
 +    * Devices: 83 
 +    * Address space: 128.195.0.0-128.195.63.255 
 +  * GPU 
 +    * Clusters: ​ 8 
 +    * GPU hosts: ​ 44  
 +    * Distributed computing managed by [[services:​slurm|Slurm]] 
  
 ===== Requirements for Equipment inside Data Center ===== ===== Requirements for Equipment inside Data Center =====
Line 16: Line 29:
 All ICS faculty and researchers are welcome to place their equipment in the ICS data center so long as the equipment has the following attributes: All ICS faculty and researchers are welcome to place their equipment in the ICS data center so long as the equipment has the following attributes:
  
-  * **Rack mountable**: ​ The equipment must rack neatly and securely into a standard 19" cabinet. +  * **Rack mountable**: ​ The equipment must rack neatly and securely into a standard 19" cabinet. Rack mount kit is required
-  * **Advanced Out of Band Management**: ​ Often called BMC, iDRAC, IPMI, ILOM, or OOB, out of band management should provide complete remote administration with a full console.. +  * **Advanced Out of Band Management**: ​ Often called BMC, iDRAC, IPMI, ILOM, or OOB, out of band management should provide complete remote administration with a full console. 
-  * **Airflow**: ​ The ICS data center is split into hot and cold aisles. ​  Any equipment in the data center must take cold air in from the cold aisle and exhaust into a hot aisle.  +  * **Trusted Platform Module (TPM)**: ​ We are encrypting Linux installs and the module allows the passphrase to be saved there to be used for autoboot
-  * **Proper Form Factor**: ​ Equipment must actually fit in a standard rack or a specialty rack must be provided. ​ Typically, this means the equipment must have a depth of 33" or less.+  * **Airflow**: ​ The ICS data center is split into hot and cold aisles. ​  Any equipment in the data center must take cold air in from the cold aisle and exhaust into a hot aisle. Typically, the means front to back airflow
 +  * **Proper Form Factor**: ​ Equipment must actually fit in a standard rack or a specialty rack must be provided. ​ Typically, this means the equipment must have a depth of 30" or less
 +    * **CAVEAT**: ​ A server with a depth of 31.5" can work if placed in a rack where the PDUs are not adjacent to each on the side of the rack
   * **IPv4**: ​ The equipment must be capable of using an IPv4 address. ​ At this time we do not offer IPv6 addresses.   * **IPv4**: ​ The equipment must be capable of using an IPv4 address. ​ At this time we do not offer IPv6 addresses.
 +  * **Power Supply Cables**: ​ The standard power cord is C13-C14. ​ There are a limited number of C19-C20 connections in the datacenter.
 +    * Ask the vendor if a C19-C14 is a viable option for powering the server (ideally 4ft).
  
 ==== Additional Requirements for Managed Equipment ==== ==== Additional Requirements for Managed Equipment ====
  
-ICS Computing support can manage equipment that comes complete with minimal warranty. ​  We cannot support self assembled or DIY builds.  ​ICS faculty ​are welcome to house these systems in the ICS data center, ​but they must be self managed.+ICS Computing support can manage equipment that comes assembled, is certified for the intended OS, and includes a minimal warranty. ​  ​ICS ​researchers ​are welcome to house any system that meets the basic requirements and self-support ​but we are unable to provide support for self assembled or DIY builds
  
 ==== Provided ==== ==== Provided ====
Line 101: Line 118:
   * Job ID 370331 for Hot/Cold Climate in Information and Computer Science has been completed.   * Job ID 370331 for Hot/Cold Climate in Information and Computer Science has been completed.
  
 +==== Portable AC Units ====
 +
 +ICS purchased 3 portable AC units with BSAS funding.
 +
 +^Name^Original Name^MAC^Location^Last Known IP^SwitchPort^Observium^
 +|Moe|poweralert-00066745cc57|00:​06:​67:​45:​cc:​57|N06| |B12/​3023-C2950S-085/​3|[[https://​observium.ics.uci.edu/​device/​device=114/​|114]]|
 +|Larry|poweralert-00066745cc50|00:​06:​67:​45:​cc:​50|A13|10.195.255.251|C1/​3023-C2950G-046/​7|[[https://​observium.ics.uci.edu/​device/​device=114/​|116]]|
 +|curly|poweralert-00066745cc51|00:​06:​67:​45:​cc:​51|H04|10.195.255.252|A04/​3023-C2950G-045/​14|[[https://​observium.ics.uci.edu/​device/​device=114/​|115]]|
  