Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
services:datacenter:cs [2024/04/17 10:25] hans [Additional Requirements for Managed Equipment] |
services:datacenter:cs [2024/12/13 08:46] (current) luciad [ICS Primary Data Center] |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== ICS Primary Data Center ====== | ====== ICS Primary Data Center ====== | ||
- | == Vital Statistics: August 2023 Census == | + | == Vital Statistics: December 2024 Census == |
* Size: 1600 sqft | * Size: 1600 sqft | ||
* HVAC: 3 Units | * HVAC: 3 Units | ||
- | * Cabinets: | + | * Cabinets: 42 |
* Servers (~800) | * Servers (~800) | ||
- | * Bare Metal: 506 | + | * Bare Metal: 598 |
* Virtual Machines: 300 | * Virtual Machines: 300 | ||
- | * [[hardware:storage|Storage]]: | + | * [[hardware:storage|Storage]] |
- | * Servers 20 | + | * Servers: 20 |
- | * Petabytes 3.2 PB | + | * Petabytes: 3.2 PB |
* [[services:network|Network]] (locally managed, 1/10/40GB) | * [[services:network|Network]] (locally managed, 1/10/40GB) | ||
* Devices: 83 | * Devices: 83 | ||
- | * Address apace 128.195.0.0-128.195.63.255 | + | * Address space: 128.195.0.0-128.195.63.255 |
- | * GPU Clusters | + | * GPU |
- | * 8 Clusters | + | * Clusters: 8 |
- | * 44 GPU Hosts | + | * GPU hosts: 44 |
* Distributed computing managed by [[services:slurm|Slurm]] | * Distributed computing managed by [[services:slurm|Slurm]] | ||
Line 29: | Line 29: | ||
All ICS faculty and researchers are welcome to place their equipment in the ICS data center so long as the equipment has the following attributes: | All ICS faculty and researchers are welcome to place their equipment in the ICS data center so long as the equipment has the following attributes: | ||
- | * **Rack mountable**: The equipment must rack neatly and securely into a standard 19" cabinet. | + | * **Rack mountable**: The equipment must rack neatly and securely into a standard 19" cabinet. Rack mount kit is required. |
- | * **Advanced Out of Band Management**: Often called BMC, iDRAC, IPMI, ILOM, or OOB, out of band management should provide complete remote administration with a full console.. | + | * **Advanced Out of Band Management**: Often called BMC, iDRAC, IPMI, ILOM, or OOB, out of band management should provide complete remote administration with a full console. |
- | * **Airflow**: The ICS data center is split into hot and cold aisles. Any equipment in the data center must take cold air in from the cold aisle and exhaust into a hot aisle. | + | * **Trusted Platform Module (TPM)**: We are encrypting Linux installs and the module allows the passphrase to be saved there to be used for autoboot. |
+ | * **Airflow**: The ICS data center is split into hot and cold aisles. Any equipment in the data center must take cold air in from the cold aisle and exhaust into a hot aisle. Typically, the means front to back airflow. | ||
* **Proper Form Factor**: Equipment must actually fit in a standard rack or a specialty rack must be provided. Typically, this means the equipment must have a depth of 30" or less. | * **Proper Form Factor**: Equipment must actually fit in a standard rack or a specialty rack must be provided. Typically, this means the equipment must have a depth of 30" or less. | ||
* **CAVEAT**: A server with a depth of 31.5" can work if placed in a rack where the PDUs are not adjacent to each on the side of the rack. | * **CAVEAT**: A server with a depth of 31.5" can work if placed in a rack where the PDUs are not adjacent to each on the side of the rack. | ||
* **IPv4**: The equipment must be capable of using an IPv4 address. At this time we do not offer IPv6 addresses. | * **IPv4**: The equipment must be capable of using an IPv4 address. At this time we do not offer IPv6 addresses. | ||
* **Power Supply Cables**: The standard power cord is C13-C14. There are a limited number of C19-C20 connections in the datacenter. | * **Power Supply Cables**: The standard power cord is C13-C14. There are a limited number of C19-C20 connections in the datacenter. | ||
- | * Ask the vendor if a C19-C14 is a viable option for powering the server. | + | * Ask the vendor if a C19-C14 is a viable option for powering the server (ideally 4ft). |
==== Additional Requirements for Managed Equipment ==== | ==== Additional Requirements for Managed Equipment ==== |